資料庫
儀器網(wǎng) >
資料庫 >Determination of agmatine in biological samples by c
Determination of agmatine in biological samples by c
本文由 北京華陽利民儀器有限公司 整理匯編
2024-09-28 00:08 674閱讀次數(shù)
文檔僅可預(yù)覽首頁內(nèi)容,請下載后查看全文信息!
立即下載
Determination of agmatine in biological samples by c
登錄或新用戶注冊
請用手機微信掃描下方二維碼 快速登錄 或注冊新賬號
微信掃碼,手機電腦聯(lián)動
更多資料
Determination of agmatine in biological samples by c
Determination of agmatine in biological samples by c[詳細(xì)]
2024-09-18 18:08
課件
Determination of agmatine in biological samples by c
Determination of agmatine in biological samples by c[詳細(xì)]
2024-09-28 00:08
專利
C, S determination in ore samples
C, S determination in ore samples[詳細(xì)]
2015-06-24 00:00
期刊論文
C, S determination in wood samples
SuitableAnalyzersnCS-580seriesnCS-2000(resistancefurnace)UsedAccessoriesn90160DisposableporcelainboatsnSuitablecalibrationmaterialfromNISTorotherSettingsnFurnaceTemperature:1350°CnComperatorlevel:20nminimumanalysistime:60secondsnmaximumanalysistime:180secondsSamplepreparationForbestresultspreparethesampledowntoaparticlesizeabout200m.Drythesampletillmassconstancyat105°C(inminimumfor1Hour).ProcedurenPrepareandcleantheELTRAanalyzer(f.e.exchangeAnhydron,Sodiumhydroxide)andsetthefurnacetemperatureto1350°CnRuninminimumthreewarmupsamples(f.e.ELTRA92511-3020)withamediumsampleweightof200mguntiltheresultsarestablenCalibratethesystemwithasuitablecalibrationmaterial(fromNISTorother):(1)Weighinasampleweightof150mginthe90160porcelainboots(2)Startanalysis(F5Button)(3)LoadthesampleintothefurnaceandwaituntilthePCcalculatesresultsRepeatStep(1)(3)inminimumforthreetimes;marktheresultsandusethecalibrationfunctioninthesoftware[詳細(xì)]
2018-08-16 10:00
產(chǎn)品樣冊
C, S determination in coal samples
SuitableAnalyzersCS-580seriesCS-2000(resistancefurnace)UsedAccessories90160DisposableporcelainboatsSuitablecalibrationmaterialfromNISTorotherSettingsFurnaceTemperature:1350°CComperatorlevel:20minimumanalysistime:60secondsmaximumanalysistime:180secondsSamplepreparationForbestresultspreparethesampledowntoaparticlesizeabout200μm.Drythesampletillmassconstancyat105°C(inminimumfor1Hour).ProcedurenPrepareandcleantheELTRAanalyzer(f.e.exchangeAnhydron,Sodiumhydroxide)andsetthefurnacetemperatureto1350°CnRuninminimumthreewarmupsamples(f.e.ELTRA92511-3020)withamediumsampleweightof200mguntiltheresultsarestablenCalibratethesystemwithasuitablecalibrationmaterial(fromNISTorother):(1)Weighinasampleweightof200mginthe90160porcelainboots(2)Startanalysis(F5Button)(3)LoadthesampleintothefurnaceandwaituntilthePCcalculatesresultsRepeatStep(1)(3)inminimumforthreetimes;marktheresultsandusethecalibrationfunctioninthesoftware->Analyzetheunknownsamples.[詳細(xì)]
2018-08-16 10:00
產(chǎn)品樣冊
C, S determination in flue ash samples
C, S determination in flue ash samples[詳細(xì)]
2015-06-24 00:00
標(biāo)準(zhǔn)
C, S determination in pure iron samples
C, S determination in pure iron samples[詳細(xì)]
2024-09-18 22:38
專利
Determination of Mercury in Biological Matrices
Determination of Mercury in Biological Matrices[詳細(xì)]
2024-09-28 22:30
選購指南
O determination in copper samples
O determination in copper samples[詳細(xì)]
2015-06-24 00:00
操作手冊
O, N determination in steel samples
O, N determination in steel samples[詳細(xì)]
2015-06-24 00:00
操作手冊
O, N determination in steel samples
O, N determination in steel samples[詳細(xì)]
2015-06-24 00:00
期刊論文
O, N determination in titanium samples
SuitableanalyzersnON900nONH2000UsedaccessoriesnInnergraphitecrucibles(90180)nOutergraphitecrucibles(90185)nNickelbasket(90250)orAR2344nSuitablecalibrationmaterial(NISTorother)SettingsnComparatorlevel:20mVnMinimumtime:15secnMaximumtime:3:00minnPostwaiting:30secnBaselinedeviation:200mV;Step:16mV;Time:10secnMode:continuousnOutgasTime:45secPower:6kWnTimePurge:20secStability:45secnIntegrationdelayIRcell:2secTCcell:10secnAnalyse(1)Time:75secPower(1):6kWPower(2):6kWSamplepreparationMakesurethatthesurfaceofthetitaniumisfreefromcontaminations;otherwisecleanthesamplewithacetonep.a.andletdryatatmosphere.ProcedurenPrepareELTRAanalyzer(exchangeanhydrone,sodiumhydroxide,copperoxidewhennecessary),cleanfurnace,sampledropmechanism,electrodetipnRunthreeblankswithemptycruciblesnCalibratetheanalyzerwithsuitablecalibrationmaterial(NISTorother)(1)Filloneemptyinnercrucible(90180)inoneoutercrucible(90185)andplacethemontheelectrodetip,closefurnace(F2Button)(2)Weighcalibrationmaterialandgiveitintoanickelbasket(90250orAR2344)(3)Placenickelbasketwithcalibrationmaterialorsampleinthesampledropmechanismandstartanalysis(F5Button)Afteranalysisgivetheinnercrucibleintowasteandfillinanewone.Theoutercruciblescanbeusedapproximately10times.Repeatsteps(1)(3)atleastthreetimes;Marktheresultsandusethecalibrationfunctioninthesoftware.[詳細(xì)]
2018-08-16 10:00
產(chǎn)品樣冊
O, N determination in steel samples (single graphite crucibles)
SuitableanalyzersnON900nONH2000UsedaccessoriesnGraphitecrucibles(90190)nSuitablecalibrationmaterial(NISTorother)SettingsnComparatorlevel:5mV(lowoxygen);20mV(other)nMinimumtime:15sec(oxygen);35sec(nitrogen)nMaximumtime:3:00minnPostwaiting:20secnBaselinedeviation:20mV;Step:16mV;Time:10secnMode:continuousnOutgasTime:45secPower:5kWnTimePurge:15secStability:45secnIntegrationdelayIRcell:2secTCcell:10secnAnalyse(1)Time:40secPower(1):4kWPower(2):4kWSamplepreparationMakesurethatthesurfaceofthesteelisfreefromcontaminations;otherwisecleanthesamplewithacetonep.a.andletdryatatmosphere.ProcedurenPrepareELTRAanalyzer(exchangeanhydrone,sodiumhydroxide,copperoxidewhennecessary),cleanfurnace,sampledropmechanism,electrodetipnRunthreeblankswithemptycruciblesnCalibratetheanalyzerwithsuitablecalibrationmaterial(NISTorother)(1)Placeemptycrucible(90190)ontheelectrodetip,closefurnace(F2Button)(2)Weighcalibrationmaterial(usuallypins)(3)Placecalibrationmaterialinthesampledropmechanismandstartanalysis(F5Button)Repeatsteps(1)(3)atleastthreetimes;Marktheresultsandusethecalibrationfunctioninthesoftware.[詳細(xì)]
2018-08-16 10:00
產(chǎn)品樣冊
O, N determination in steel samples (Inner and outer graphite crucibles)
SuitableanalyzersnON900nONH2000UsedaccessoriesnInnergraphitecrucibles(90180)nOutergraphitecrucibles(90185)nSuitablecalibrationmaterial(NISTorother)SettingsnComparatorlevel:5mV(lowoxygen);20mV(other)nMinimumtime:15sec(oxygen);35sec(nitrogen)nMaximumtime:3:00minnPostwaiting:20secnBaselinedeviation:20mV;Step:16mV;Time:10secnMode:continuousnOutgasTime:45secPower:5kWnTimePurge:15secStability:45secnIntegrationdelayIRcell:2secTCcell:10secnAnalyse(1)Time:40secPower(1):4kWPower(2):4kWSamplepreparationMakesurethatthesurfaceofthesteelisfreefromcontaminations;otherwisecleanthesamplewithacetonep.a.andletdryatatmosphere.ProcedurenPrepareELTRAanalyzer(exchangeanhydrone,sodiumhydroxide,copperoxidewhennecessary),cleanfurnace,sampledropmechanism,electrodetipnRunthreeblankswithemptycruciblesnCalibratetheanalyzerwithsuitablecalibrationmaterial(NISTorother)(1)Filloneemptyinnercrucible(90180)inoneoutercrucible(90185)andplacethemontheelectrodetip,closefurnace(F2Button)(2)Weighcalibrationmaterial(usuallypins)(3)Placecalibrationmaterialinthesampledropmechanismandstartanalysis(F5Button)Afteranalysisgivetheinnercrucibleintowasteandfillinanewone.Theoutercruciblescanbeusedapproximately10times.Repeatsteps(1)(3)atleastthreetimes;Marktheresultsandusethecalibrationfunctioninthesoftware.[詳細(xì)]
2018-08-16 10:00
產(chǎn)品樣冊
Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES
Traditionally, geological samples are analyzed using flame atomic absorption (FAAS) and/or radial ICP-OES with a vertical torch. Achieving high sample throughput at a low cost per analysis for geochemical samples can be challenging when using these techniques. [詳細(xì)]
2024-09-29 22:17
標(biāo)準(zhǔn)
Viscosity measurement of LDPE samples
Viscosity measurement of LDPE samples[詳細(xì)]
2008-06-13 00:00
其它
Phenol extraction of DNA samples
Phenol extraction of DNA samples[詳細(xì)]
2016-03-17 00:00
標(biāo)準(zhǔn)
Physical Basis of Structure of Biological Macromolec
Physical Basis of Structure of Biological Macromolec[詳細(xì)]
2024-09-28 00:05
產(chǎn)品樣冊
Structure and biological activity of pathogen-like s
Structure and biological activity of pathogen-like s[詳細(xì)]
2024-09-20 13:30
產(chǎn)品樣冊
ISOLATION OF THYROXINE FROM AQUEOUS SAMPLES
ISOLATION OF THYROXINE FROM AQUEOUS SAMPLES[詳細(xì)]
2006-07-20 00:00
專利
Copyright 2004-2026 yiqi.com All Rights Reserved , 未經(jīng)書面授權(quán) , 頁面內(nèi)容不得以任何形式進(jìn)行復(fù)制
參與評論
登錄后參與評論