資料庫
O, N determination in steel samples
本文由 弗爾德(上海)儀器設(shè)備有限公司 整理匯編
2015-06-24 00:00 805閱讀次數(shù)
文檔僅可預(yù)覽首頁內(nèi)容,請下載后查看全文信息!
立即下載
O, N determination in steel samples
登錄或新用戶注冊
請用手機微信掃描下方二維碼 快速登錄 或注冊新賬號
微信掃碼,手機電腦聯(lián)動
更多資料
O, N determination in steel samples
O, N determination in steel samples[詳細(xì)]
2015-06-24 00:00
操作手冊
O, N determination in steel samples
O, N determination in steel samples[詳細(xì)]
2015-06-24 00:00
期刊論文
O, N determination in steel samples (single graphite crucibles)
SuitableanalyzersnON900nONH2000UsedaccessoriesnGraphitecrucibles(90190)nSuitablecalibrationmaterial(NISTorother)SettingsnComparatorlevel:5mV(lowoxygen);20mV(other)nMinimumtime:15sec(oxygen);35sec(nitrogen)nMaximumtime:3:00minnPostwaiting:20secnBaselinedeviation:20mV;Step:16mV;Time:10secnMode:continuousnOutgasTime:45secPower:5kWnTimePurge:15secStability:45secnIntegrationdelayIRcell:2secTCcell:10secnAnalyse(1)Time:40secPower(1):4kWPower(2):4kWSamplepreparationMakesurethatthesurfaceofthesteelisfreefromcontaminations;otherwisecleanthesamplewithacetonep.a.andletdryatatmosphere.ProcedurenPrepareELTRAanalyzer(exchangeanhydrone,sodiumhydroxide,copperoxidewhennecessary),cleanfurnace,sampledropmechanism,electrodetipnRunthreeblankswithemptycruciblesnCalibratetheanalyzerwithsuitablecalibrationmaterial(NISTorother)(1)Placeemptycrucible(90190)ontheelectrodetip,closefurnace(F2Button)(2)Weighcalibrationmaterial(usuallypins)(3)Placecalibrationmaterialinthesampledropmechanismandstartanalysis(F5Button)Repeatsteps(1)(3)atleastthreetimes;Marktheresultsandusethecalibrationfunctioninthesoftware.[詳細(xì)]
2018-08-16 10:00
產(chǎn)品樣冊
O, N determination in steel samples (Inner and outer graphite crucibles)
SuitableanalyzersnON900nONH2000UsedaccessoriesnInnergraphitecrucibles(90180)nOutergraphitecrucibles(90185)nSuitablecalibrationmaterial(NISTorother)SettingsnComparatorlevel:5mV(lowoxygen);20mV(other)nMinimumtime:15sec(oxygen);35sec(nitrogen)nMaximumtime:3:00minnPostwaiting:20secnBaselinedeviation:20mV;Step:16mV;Time:10secnMode:continuousnOutgasTime:45secPower:5kWnTimePurge:15secStability:45secnIntegrationdelayIRcell:2secTCcell:10secnAnalyse(1)Time:40secPower(1):4kWPower(2):4kWSamplepreparationMakesurethatthesurfaceofthesteelisfreefromcontaminations;otherwisecleanthesamplewithacetonep.a.andletdryatatmosphere.ProcedurenPrepareELTRAanalyzer(exchangeanhydrone,sodiumhydroxide,copperoxidewhennecessary),cleanfurnace,sampledropmechanism,electrodetipnRunthreeblankswithemptycruciblesnCalibratetheanalyzerwithsuitablecalibrationmaterial(NISTorother)(1)Filloneemptyinnercrucible(90180)inoneoutercrucible(90185)andplacethemontheelectrodetip,closefurnace(F2Button)(2)Weighcalibrationmaterial(usuallypins)(3)Placecalibrationmaterialinthesampledropmechanismandstartanalysis(F5Button)Afteranalysisgivetheinnercrucibleintowasteandfillinanewone.Theoutercruciblescanbeusedapproximately10times.Repeatsteps(1)(3)atleastthreetimes;Marktheresultsandusethecalibrationfunctioninthesoftware.[詳細(xì)]
2018-08-16 10:00
產(chǎn)品樣冊
O, N determination in titanium samples
SuitableanalyzersnON900nONH2000UsedaccessoriesnInnergraphitecrucibles(90180)nOutergraphitecrucibles(90185)nNickelbasket(90250)orAR2344nSuitablecalibrationmaterial(NISTorother)SettingsnComparatorlevel:20mVnMinimumtime:15secnMaximumtime:3:00minnPostwaiting:30secnBaselinedeviation:200mV;Step:16mV;Time:10secnMode:continuousnOutgasTime:45secPower:6kWnTimePurge:20secStability:45secnIntegrationdelayIRcell:2secTCcell:10secnAnalyse(1)Time:75secPower(1):6kWPower(2):6kWSamplepreparationMakesurethatthesurfaceofthetitaniumisfreefromcontaminations;otherwisecleanthesamplewithacetonep.a.andletdryatatmosphere.ProcedurenPrepareELTRAanalyzer(exchangeanhydrone,sodiumhydroxide,copperoxidewhennecessary),cleanfurnace,sampledropmechanism,electrodetipnRunthreeblankswithemptycruciblesnCalibratetheanalyzerwithsuitablecalibrationmaterial(NISTorother)(1)Filloneemptyinnercrucible(90180)inoneoutercrucible(90185)andplacethemontheelectrodetip,closefurnace(F2Button)(2)Weighcalibrationmaterialandgiveitintoanickelbasket(90250orAR2344)(3)Placenickelbasketwithcalibrationmaterialorsampleinthesampledropmechanismandstartanalysis(F5Button)Afteranalysisgivetheinnercrucibleintowasteandfillinanewone.Theoutercruciblescanbeusedapproximately10times.Repeatsteps(1)(3)atleastthreetimes;Marktheresultsandusethecalibrationfunctioninthesoftware.[詳細(xì)]
2018-08-16 10:00
產(chǎn)品樣冊
O determination in copper samples
O determination in copper samples[詳細(xì)]
2015-06-24 00:00
操作手冊
O, N determination in titanium
O, N determination in titanium[詳細(xì)]
2024-09-28 04:37
產(chǎn)品樣冊
C, S determination in ore samples
C, S determination in ore samples[詳細(xì)]
2015-06-24 00:00
期刊論文
C, S determination in wood samples
SuitableAnalyzersnCS-580seriesnCS-2000(resistancefurnace)UsedAccessoriesn90160DisposableporcelainboatsnSuitablecalibrationmaterialfromNISTorotherSettingsnFurnaceTemperature:1350°CnComperatorlevel:20nminimumanalysistime:60secondsnmaximumanalysistime:180secondsSamplepreparationForbestresultspreparethesampledowntoaparticlesizeabout200m.Drythesampletillmassconstancyat105°C(inminimumfor1Hour).ProcedurenPrepareandcleantheELTRAanalyzer(f.e.exchangeAnhydron,Sodiumhydroxide)andsetthefurnacetemperatureto1350°CnRuninminimumthreewarmupsamples(f.e.ELTRA92511-3020)withamediumsampleweightof200mguntiltheresultsarestablenCalibratethesystemwithasuitablecalibrationmaterial(fromNISTorother):(1)Weighinasampleweightof150mginthe90160porcelainboots(2)Startanalysis(F5Button)(3)LoadthesampleintothefurnaceandwaituntilthePCcalculatesresultsRepeatStep(1)(3)inminimumforthreetimes;marktheresultsandusethecalibrationfunctioninthesoftware[詳細(xì)]
2018-08-16 10:00
產(chǎn)品樣冊
C, S determination in coal samples
SuitableAnalyzersCS-580seriesCS-2000(resistancefurnace)UsedAccessories90160DisposableporcelainboatsSuitablecalibrationmaterialfromNISTorotherSettingsFurnaceTemperature:1350°CComperatorlevel:20minimumanalysistime:60secondsmaximumanalysistime:180secondsSamplepreparationForbestresultspreparethesampledowntoaparticlesizeabout200μm.Drythesampletillmassconstancyat105°C(inminimumfor1Hour).ProcedurenPrepareandcleantheELTRAanalyzer(f.e.exchangeAnhydron,Sodiumhydroxide)andsetthefurnacetemperatureto1350°CnRuninminimumthreewarmupsamples(f.e.ELTRA92511-3020)withamediumsampleweightof200mguntiltheresultsarestablenCalibratethesystemwithasuitablecalibrationmaterial(fromNISTorother):(1)Weighinasampleweightof200mginthe90160porcelainboots(2)Startanalysis(F5Button)(3)LoadthesampleintothefurnaceandwaituntilthePCcalculatesresultsRepeatStep(1)(3)inminimumforthreetimes;marktheresultsandusethecalibrationfunctioninthesoftware->Analyzetheunknownsamples.[詳細(xì)]
2018-08-16 10:00
產(chǎn)品樣冊
Determination of agmatine in biological samples by c
Determination of agmatine in biological samples by c[詳細(xì)]
2024-09-18 18:08
課件
Determination of agmatine in biological samples by c
Determination of agmatine in biological samples by c[詳細(xì)]
2024-09-28 00:08
專利
C, S determination in flue ash samples
C, S determination in flue ash samples[詳細(xì)]
2015-06-24 00:00
標(biāo)準(zhǔn)
C, S determination in pure iron samples
C, S determination in pure iron samples[詳細(xì)]
2024-09-18 22:38
專利
皮爾茲PNOZ s5 24VDC 2 n/o 2 n/o t
皮爾茲安全繼電器PNOZs524VDC2n/o2n/ot批準(zhǔn):CE,cULus認(rèn)證,TV,KOSHA,CCC應(yīng)用選項:安全門監(jiān)控,瞬時緊急停止監(jiān)控,限位開關(guān),緊急停止延時監(jiān)控,光柵設(shè)備監(jiān)控器。4級,光柵設(shè)備監(jiān)控器。2級,非典型,光柵設(shè)備監(jiān)控器。2級,典型值,安全斷電延時計時器操作模式:單通道,自動復(fù)位,雙通道,手動復(fù)位,觸點間短路檢測,啟動測試,手動復(fù)位監(jiān)控,不檢測觸點間短路,自檢測,編程延時斷電產(chǎn)品標(biāo)準(zhǔn):EN60947-5-1標(biāo)準(zhǔn):EN60204-1,EN62061,ENISO13849-1,VDE0113-1供電電壓(V):24,0源型:DC終端型:插件皮爾茲安全繼電器PNOZs524VDC2n/o2n/ot終端類型:螺絲端子瞬時安全觸點數(shù)量:2延時安全觸點數(shù)量:2半導(dǎo)體輸出數(shù)量:1可選次數(shù):0.04s,0.10s,0.20s,0.30s,0.40s,0.50s,0.60s,0.70s,0.80s,1.00s,1.50s,10.00s,100.00s,12.00s,120.00s,14.00s,140.00s,15.00s,150.00s,16.00s,160.00s,180.00s,2.00s,2.50s,20.00s,200.00s,210.00s,240.00s,25.00s,3.00s,3.50s,30.00s,300.00s,35.00s,4.00s,40.00s,5.00s,50.00s,6.00s,60.00s,7.00s,70.00s,8.00s,80.00s,90.00s停止類別:0/1在DC13處的Zda電流I(6個循環(huán)/Z小):4.0A在AC1處的Zda電流5:3.0A寬度尺寸:22.5mm高度尺寸:98.0mm深度尺寸:120.0mm總重:245g凈重:235g以攝氏度一表示的環(huán)境溫度:-10-55°C皮爾茲安全繼電器PNOZs524VDC2n/o2n/ot[詳細(xì)]
2018-10-02 10:01
產(chǎn)品樣冊
Determination of trace elements in steel using the Agilent 7900 ICP-MS
Monitoring and control領(lǐng) the level of trace element impurities in metals and alloys is important, as impurities can affect the properties of the metal and may degrade the functionality of the finished component.[詳細(xì)]
2024-09-24 10:13
標(biāo)準(zhǔn)
Thermo Scientific?46i-HL型N?O分析儀
46i-HL型高濃度分析儀使用極ng確的校準(zhǔn)曲線,保證了儀器在2,000 ppm的濃度范圍內(nèi)有準(zhǔn)確的線性輸出,并且可以在雙量程和自動量程模式中使用。此外,46i-HL型高濃度分析儀還具有自動壓力和溫度補償功能,增強了對沖擊和振動的抵抗力,同時提高了產(chǎn)品的特性和靈敏性。[詳細(xì)]
2020-01-15 15:30
產(chǎn)品樣冊
Thermo Scientific? 46i型N?O分析儀
46i型分析儀使用極ng確的校準(zhǔn)曲線,保證了儀器在50ppm的濃度范圍內(nèi)有準(zhǔn)確的線性輸出,并且可以在雙量程和自動范圍模式中使用。[詳細(xì)]
2024-09-29 10:04
產(chǎn)品樣冊
PILZ繼電器PNOZ s3 24VDC 2 n/o
PILZ繼電器PNOZs324VDC2n/o技術(shù)參數(shù)[詳細(xì)]
2018-11-23 10:00
產(chǎn)品樣冊
Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES
Traditionally, geological samples are analyzed using flame atomic absorption (FAAS) and/or radial ICP-OES with a vertical torch. Achieving high sample throughput at a low cost per analysis for geochemical samples can be challenging when using these techniques. [詳細(xì)]
2024-09-29 22:17
標(biāo)準(zhǔn)
Copyright 2004-2026 yiqi.com All Rights Reserved , 未經(jīng)書面授權(quán) , 頁面內(nèi)容不得以任何形式進(jìn)行復(fù)制
參與評論
登錄后參與評論