国产三级在线看完整版-内射白嫩大屁股在线播放91-欧美精品国产精品综合-国产精品视频网站一区-一二三四在线观看视频韩国-国产不卡国产不卡国产精品不卡-日本岛国一区二区三区四区-成年人免费在线看片网站-熟女少妇一区二区三区四区

儀器網(wǎng)(yiqi.com)歡迎您!

| 注冊(cè)2 登錄
網(wǎng)站首頁-資訊-話題-產(chǎn)品-評(píng)測(cè)-品牌庫-供應(yīng)商-展會(huì)-招標(biāo)-采購(gòu)-知識(shí)-技術(shù)-社區(qū)-資料-方案-產(chǎn)品庫-視頻

應(yīng)用方案

儀器網(wǎng)/ 應(yīng)用方案/ 當(dāng)溫濕度控制器顯示濕度異常的狀況,怎么辦呢?

立即掃碼咨詢

聯(lián)系方式:15876446198

聯(lián)系我們時(shí)請(qǐng)說明在儀器網(wǎng)(m.sdczts.cn)上看到的!

掃    碼    分   享

【概述Summarize】當(dāng)溫濕度控制器顯示濕度異常的狀況,該如何辨別以及解決?

When the temperature humidity controller shows the condition of abnormal humidity, how ?


恒溫箱主要用于測(cè)試和確定電工、電子及其他產(chǎn)品及材料進(jìn)行高溫、低溫、交變濕熱度或恒定試驗(yàn)的溫度環(huán)境變化后的參數(shù)及性能。Thermostat is main used for testing and determining the parameters and performance of electrical and electronic and other products and materials after the temperature environment changes in high and low temperature alternating humidity and heat degree or constant test.


【檢查步驟 Check Steps

  1. 查看控制機(jī)房的欠水超溫保護(hù)器,是否設(shè)定在150℃的位置。

    Check whether the under-water and over-temperature protector in the control unit is set at the position of 150 Celsius.

  2. 查看機(jī)房?jī)?nèi),管路是否過臟,造成水流不順。

    Check the unit, whether the pipeline is too dirty, causing water flow.

  3. 查看上水箱是否有水,如果沒有水,再查看下水箱是否有水。

    Check whether has water in top water tank, if not, same to check the bottom water tank.

  4. 查看是否濕度部份的固態(tài)繼電器燒毀短路: 如果加熱器未燒毀,使用三用電表交流電壓檔,電壓檔位開到600伏特的位置,將紅黑棒分別放在線號(hào)標(biāo)注為H的那一顆固態(tài)繼電器交流兩側(cè),將濕度部份的濕度設(shè)定值設(shè)置0%,此時(shí)濕度部份的固態(tài)繼電器的指示燈不會(huì)亮起,如果量測(cè)的電壓值沒有變化,維持在10V以下代表固態(tài)繼電器燒毀呈現(xiàn)短路狀態(tài)。或者首先將濕度部份設(shè)定值設(shè)為0%,再看機(jī)房?jī)?nèi)加濕桶是否水在煮沸狀態(tài)。

    Check if the humidity of solid state relay burned short-circuit: if heater is not burning, used three meters ac voltage, the position of the gear drive voltage to 600 volts, will be red and black on the annotation of line number for H that a solid state relay communication on both sides, set the humidity of humidity value 0%, humidity at this time of the light on the solid state relay can't light up, if the measured voltage value did not change, keep under 10 v represents the solid state relay burned present state of short circuit Or the first set of 0% humidity part of the set value, then see whether humidifying barrels of water inside the room in the boiling state.


【解決辦法 Solutions

  1. 1、將欠水超溫保護(hù)器轉(zhuǎn)至150℃的位置。

    Turn under-water over-temperature protector to position 150 Celsius.

  2. 2、首先將機(jī)臺(tái)后方總電源關(guān)上,然后將加濕桶下方的排水閥,打開到與管路平行的位置,帶上水箱的水都排光的時(shí)候,利用板手將加濕桶打開,將內(nèi)部因長(zhǎng)期做濕度的水垢清除,然后將硅膠管路拔除,在水中搓洗。保養(yǎng)完畢后按照拆除的方式,反方向裝回去。裝置完畢后,需將加濕桶下方的排水閥,關(guān)閉到與管路垂直的位置,然后再將機(jī)臺(tái)后方總電源打開。

    Firstly to turn off the total power supply behind the machine, then open the drainage valve under the humidifying barrel, till to a position parallel to the pipe line. Water shortage from top water tank, open the humidifying barrel by the spanner, scale removal and silica gel tube was removed, clean in water. After the maintenance in accordance with the demolition mode, put it back in the opposite direction, after installation, turn on the drainage valve with the pipeline on the vertical position, then turn on the total power supply.

  3. 3、下水箱都無水,將下水箱加水,即可解決。上水箱如果沒有水,下水箱有水,則為下水箱打水馬達(dá)壞掉,通知皓天黃工維修客服部門上門進(jìn)行維修; 

    There is no water in the bottom tank, will add water in that tank, solve it ! If there is no water in the top tank, there is water in bottom tank, the bottom tank to drain water, means the motor broken. So inform the maintenance customer service department of Haotian company to conduct on-site.

  4. 4、更換濕度部份的固態(tài)繼電器(線號(hào)標(biāo)注為H的那一顆固態(tài)繼電器),或者通知黃工售后上門進(jìn)行維修。

    Replace the solid state relay of the humidity part (the one marked with line No. H), or notify the after sales staff to conduct on-site maintenance.


相關(guān)產(chǎn)品

參與評(píng)論

全部評(píng)論(0條)

推薦方案

當(dāng)溫濕度控制器顯示濕度異常的狀況,怎么辦呢?
當(dāng)溫濕度控制器顯示溫度異常的狀況,皓天來幫您
高低溫交變濕熱試驗(yàn)箱溫濕度控制器顯示濕度異常的故障及解決辦法
溫濕度控制器顯示異常,按鈕點(diǎn)擊無動(dòng)作
恒溫恒濕試驗(yàn)箱溫濕度控制器顯示異常的解決方案
溫濕度控制器顯示溫度異常(超溫報(bào)警)的故障及解決方法
高低溫交變濕熱試驗(yàn)箱溫濕度控制器顯示壓力異常的故障及解決辦法
控制器顯示缺水報(bào)警(水位異常)的故障怎么解決?
當(dāng)溫度采集儀上測(cè)得的溫度與控制器上顯示的差距大
應(yīng)對(duì)恒溫恒濕試驗(yàn)箱溫濕度控制器顯示故障的全面指南
可程式恒溫恒濕箱濕度突然顯示100%
恒溫恒濕試驗(yàn)箱濕度降不下去怎么辦?
恒溫恒濕試驗(yàn)箱濕度降不下去可能是由多種原因引起的,需要逐步排查和解決。以下是常見原因及解決方法:
恒溫恒濕試驗(yàn)箱控制器出現(xiàn)故障了怎么辦
當(dāng)恒溫恒濕的濕度上不去的時(shí)候怎么解決
當(dāng)恒溫恒濕設(shè)備的濕度無法達(dá)到設(shè)定值時(shí),可以采取以下措施
恒溫恒濕試驗(yàn)箱無法操作控制該怎么辦呢?
小型模擬環(huán)境試驗(yàn)設(shè)備溫濕度顯示的破解之道
基于DSP的數(shù)字化溫濕度智能控制器設(shè)計(jì).pdf
恒溫恒濕試驗(yàn)箱溫濕度控制器出現(xiàn)異常解決方法
恒溫恒濕試驗(yàn)箱的濕度無法達(dá)到設(shè)定值該怎么辦?
恒溫恒濕試驗(yàn)箱濕度無法達(dá)到設(shè)定值,可從以下幾個(gè)方面進(jìn)行排查和解決:
高低溫試驗(yàn)箱在使用中冰堵了該怎么辦呢?

在線留言

上傳文檔或圖片,大小不超過10M
換一張?
取消