資料庫
儀器網(wǎng)>
資料庫>Standard-compliant element analysis of silicon carbide and mixtures containing silicon carbide with combustion analyzers
Standard-compliant element analysis of silicon carbide and mixtures containing silicon carbide with combustion analyzers
-
本文由 弗爾德(上海)儀器設(shè)備有限公司 整理匯編
2015-06-24 00:00 919閱讀次數(shù)
文檔僅可預(yù)覽首頁內(nèi)容,請下載后查看全文信息!
-
立即下載
Standard-compliant element analysis of silicon carbide and mixtures containing silicon carbide with combustion analyzers
登錄或新用戶注冊
請用手機微信掃描下方二維碼
快速登錄或注冊新賬號
微信掃碼,手機電腦聯(lián)動
更多資料
-
Standard-compliant element analysis of silicon carbide and mixtures containing silicon carbide with combustion analyzers
- Standard-compliant element analysis of silicon carbide and mixtures containing silicon carbide with combustion analyzers[詳細(xì)]
-
2015-06-24 00:00
產(chǎn)品樣冊
-
Standard-compliant element analysis of silicon carbide and mixtures containing silicon carbide with
- Elementalanalyzersareimportanttoolsforqualitycontrolofawiderangeofproducts.Avarietyofmatrices,suchasceramics,coal,steelorsoil,canbeanalyzedfortheirelementconcentrationswithdifferenttypesofinstruments.TheproductrangeofEltraGmbH,locatednearDüsseldorf,Germany,comprisesanalyzersforC,H,N,S,Oandthermogravimetrywhichallowforthestandard-compliantdeterminationofcarboninvariouschemicalbondings,aswellasoxygenandnitrogeninSiCandinmaterialscontainingSiC.Therequirementswhichhavetobefulfilledforastandard-compliantanalysismay,however,varygreatly,dependingonthedesiredparameters.1IntroductionSiliconcarbidehasahighmeltingpointof2,700°Candisthereforeanimportantrawmaterialforrefractoryandceramicproducts.AnothercharacteristicofSiCisitsresistanceagainstchlorineandstrongacids,alsoathightemperatures.Thankstoahardnessof9.6Mohs,itisalsousedinthemetallurgicalindustryfortheproductionofabrasivesandpolish.TheEuropeanstandardseriesENISO21068(2008)regulatethechemicalanalysisofsiliconcarbideandrawmaterialscontainingsiliconcarbide.Part1dealswithsamp領(lǐng),part2withthechemicalanalysisofcarbon,siliconandlossofignitionandpart3coversmetalanalysisanddeterminationofoxygenandnitrogenconcentrations.Eltracombustionanalyzersarewellsuitedforthequalitycontrolofrefractoryandceramicproductswhichcontainsiliconcarbide.Thisarticleoutlinesthepossibilitiesandlimitsofelementalanalyzerswhendea領(lǐng)withthesematerials.2ThermogravimetricparametersThedeterminationofthermogravimetricparameterssuchas,forexample,lossofignition,isdescribedinthesecondpartofISO21068.Thermogravimetryisbasedonthecontinuousrecordingofmasschangesasafunctionofacombinationoftime,temperatureandatmosphere.Thestandardclearlydefinestheuseofmufflefurnacesandbalancesforthisprocess.Allmethodsdescribedinthestandarduseadefinedsamplecontainermadeofsteel,ceramicmaterialorplatinumwhichispreheatedattheprescribedtemperaturebetween250°Cand1050°C.Thesampleweightisnotalwaysdefined(e.g.lossondryingLOD250)orrangesfrom25gto1kg(changeofmassinairat200°Cand400°C).Afterweighingthesampleandapplyingthedefinedtemperatureprogram(e.g.forLOI850,heatingupto850°Candmaintainingfor3h),thehotcruciblesneedtocooldowninthedesiccatorandarethenweighed.Thermogravimetricanalyzerswhichareequippedwithacombinationoffurnaceandbalanceconsiderablysimplifythemanualprocedure.Usually,theseanalyzershaveaninteriorchamberwhichcanbeheatedupto1,000°Candaseparateweighingcellintheanalysischamberwhichisconnectedwiththefurnacebyaceramicpedestal.Arotatingcarouselplacesupto19differentsamples,oneaftertheother,onthepedestaltobeweighed.Themarketoffersthermogravimetricanalyzersforbothsmallsamplequantities(e.g.20mg)andquantitiesof5gormore(suchasEltra’sThermostep,fig.1).Byusinganemptyreferencecrucible,thermalbuoyancyiscompensatedandmeasurementscanbecarriedoutreliablyevenathightemperatures.Theceramiccruciblesusuallyhaveavolumeof12ml,allowingforsampleweightsofupto5g.This,however,isnotverypracticalduetothehighfil領(lǐng)level.Sofar,theDINENISO21068-2standarddoesnotmentionautomatedthermogravimetricanalysis.IfathermogravimetricanalyzerisusedforthedeterminationofLOI850(lossonignitionat850°C),thespecificationsofthestandardcanbemettoahighdegree,ifnot1**%.ForaseriesofteststhestandardEuronormCRMNo.781-1wasweighedintocrucibleswhichhadbeenpreheatedto850°CinEltra’sThermostep.Figure2showsatypicalmeasurementcurve,table1containsthecorrespondingresults.Thestandardwasfirstdriedat105°Covernightandthen3crucibleswerefilledwith1geach.TheLOI850valuemeasuredwiththeThermostepcorrelateswellwiththevalueoffreecarbonstipulatedinthestandard.Anadvantageofthethermogravimetricmethodisthefactthatthesamples,afterhavingbeenheated,arenotsubmittedtoambientair;however,duetotheselectedweighingandmeasurementprocessitonlyrepresentsanapproximationtotheISOstandard.Currentlythemethodcannotbeadaptedtofurtherparameterswhichispartlyduetotherequiredhightemperature(LOI1050)resp.tothelargesampleweights(LOI200with1kgsamplevolume).Duetothemissingreferencematerial,validationoftheprocessremainsadifficulttask.3Determinationofthecarboncontent3.1DeterminationoftotalcarbonPart2oftheISO21068seriesalsodescribestheanalysisofsiliconcarbideanditscarboncontent.AcarefuldifferentiationhastobemadebetweenthetotalcarboncontentandtheSiC-boundcarboncontent.Dependingontherelationofthetwobondings,differentanalysismethodsarestipulatedinthestandard.Therearevariouswaystodeterminethetotalcarboncontentinsiliconcarbidesamples,whichdifferinthecombustionmethod(resistanceorinductionfurnace)andinthedetectionmethod.Coulometric,gravimetricandconductometricmethodsdon’trequirecalibration.Thecarboncontentcanbedeterminedbymeasuringtheweight,theelectricchargeortheconductivity.Forthesedetectionmethodstherequirementofchemicalsishigh;moreover,themarketdoesn’tofferadequateinstruments.Alternativeprocedurespermittedbythestandardincludetheuseofelementalanalyzerswithinductionfurnace(EltraCS-800)orresistancefurnace(EltraCS-580)aswellasdetectionwithinfraredcells.AcombinationofthetwocombustiontechnologiesandacombinedusageofthedetectorshavebeenrealizedinEltra’sCS-2000analyzer(fig.3).Fig.3:ELTRA’sCS-2000featurestheuniqueDualFurnaceTechnologyResistancefurnaceswithceramictubeoperateatlowertemperaturesthaninductionfurnaces.Theceramiccombustiontubesallowforamaximumtemperatureof1,500°C.TosafelyoxidatethetotalcarboninthesiliconcarbidetoCO2,resistancefurnacesrequiretheadditionofacceleratorssuchasleadborateortinpowder.Duetoatemperatureofapprox.2,500°Ctheoxidationofsiliconcarbidetendstotakeplacemorequicklyandmorereliablyinaninductionfurnace;moreover,themeasurementresultsshowfewervariations(seetable2).Whereastheacceleratorsfortheresistancefurnacesareusedforoxidation(leadborate)orlocaltemperaturerise(tinpowder),themetalacceleratorsusedininductionfurnacesarerequiredtoensurecombustioninthefirstplace,assiliconcarbidehasnoproperelectricconductivity.Aclearerdefinitionofthecalibrationmethodsforthevariousprocedureswouldbeawelcomeextensionofthestandard.Though[1-2]mentionsuitablecalibrationmaterials,thecalibrationwithgraphiteorcalciumcarbonateisonlydescribedindetailforthedetectionmethodwiththermalconductivitycells(chapter5.4.5).Theresultsshownintable2wereobtainedbycalibrationwithgraphite.3.2DeterminationoffreecarbonThisparametercanbeeasilydeterminedwithelementalanalyzers.Thestandardstipulatestheuseofananalyzerwithresistancefurnaceandinfrareddetection;howeverthedirectdeterminationislimited(chapter6.4.1).Astheupperlimitforthefreecarboncontentisgivenwith2%,analysissolelybycombustion,forexampleoftheEuronormstandardCRM781-1withaninformativevalueof37.22%isnotpermitted.Thus,characterizationoffreecarbonbydirectcombustionispracticallylimitedtopuresiliconcarbide.Tomeasureverylowconcentrations,thestandardspecifiestheuseofaquartztube(asisused,forexample,inEltra’sCW-800analyzer).Theanalyzerdescribedinchapter3.1ofthisarticleisnotsuitableforthisapplication;duetotheusageofdifferentfurnaces,ceramictubescannotsimplybeexchangedforquartztubes.Duetotheirpermeablestructureceramictubesarenotsuitedforthedeterminationofverylowconcentrations.Table3showstheresultsofastandardcompliantanalysisofthereferencematerialBAM-S003andadditionallyoftheEuronorm781-1standard,carriedoutwithEltra’sCW-800.Thestandardwasalsomeasuredwithananalyzerwithceramiccombustiontube(EltraCS-580).Theresultsintable3clearlysupporttheusageofafurnacewithquartztubewhenanalyzinglowcarbonconcentrations.Iftheconcentrationsaresufficientlyhigh,analyzerswithceramictubescanalsoprovidemeaningfulmeasurementresults.Inthiscase,thecalibrationoftheelementalanalyzerisofgreatimportance.Whereashigherconcentrationscanbeeasilycalibratedwithgraphite(1**%carbon)orpurecalciumcarbonate(12%carbon),lowconcentrationscanonlybecalibratedeitherwithanexpensivereferencematerialorasyntheticcarbonstandard.3.3DeterminationofthesiliconcarbidecontentTheSiCcontentcanbedeterminedfromthedifferencebetweentotalcarbonandfreecarboncontent;however,thisisonlypermissiblewhenthefreecarboncontentis50%orlessofthetotalcarboncontent.Thisapplies,forexample,totheBAMS-003standardbutnottoCRM781-1.Iftherelationbetweenfreeandboundcarbonismorethan25%,adirectanalysisispossible.IftheCRM781-1sampleisfreedofsurfacecarbon(table3),itcanbeanalyzeddirectlywithaninductionorresistancefurnace(table4).4AnalysisofoxygenandnitrogenThethirdpartoftheDINEN21068seriesdealswiththedeterminationofoxygenandnitrogen.Incontrasttothedeterminationofcarbonspecies,thesampleneedstobeheatedinaninertgasflow(helium)tomeasureitsoxygenandnitrogencontent.Theinertgasfusionmethodhasbeenestablishedformanyyearsandisalsousedforanalyzingmetals.Thestipulatedtemperatureofapprox.2,800°Ccanonlyberealizedinanelectrode/impulsefurnace.Anupperandalowerelectrodeapplyvoltagetothegraphitecruciblecontainingthesamplewhichhaspreviouslybeenpurgedwithinertgas.Theanalysisqualityisstronglyinfluencedbythepowerlineavailable(approx.5kWrecommended)andthepurityofthefluxused(nickelbasketsorcapsules).Thesematerialsarebasicallyusedformeltingpointreductiontoreleasethegassescontainedinthesiliconcarbidefromthemoltensample.Table5showstheresultsfortheBAMS-003standardobtainedwithEltra’sONH-2000analyzer.Theanalysiswascarriedoutwithpre-edgednickelbasketsanda5kWpowerline.Aftercalibrationwithacertifiedsteelstandard,goodcompliancewiththecertified/informativevalueswasachieved.Primarysubstances(suchasKNO3)canalsobeusedforcalibration;however,thesesubstancesneedtobedissolvedanddilutedfirst,andarethendriedinnickelcapsules.Themeasuringprincipledoesnotallowfordirectanalysisofliquidstandards.Theinertgasfusionprocedurecanbeeasilyappliedtotheanalysisofotherceramicswithhighnitrogen(e.g.Si3N4)oroxygen(e.g.SiO2,ZrO2)content.5ConclusionAcomprehensiveanalysisofsiliconcarbideandmixturescontainingsiliconcarbideinaccordancewiththeDINENISO21068standardseriesinvolvessophisticatedtechnicalequipment.Ifthedeterminationofmetals,notelaboratedoninthisarticle,istakenintoaccountaswell,theadditionaluseofspectrometers(ICP,OES,XRF)iscalledfor.Themarketoffersanalyzersforstandard-compliantanalysisofcarbonconcentrations;however,differentanalysisspecificationsrequiredifferentconfigurations(inductionfurnace,combustioninceramicorquartzglasstube).Oxygenandnitrogenareeasilyandreliablydeterminedwithanalyzersusinginertgasfusion.Forafutureupdateofthestandardamoreextensivetreatmentofthermogravimetricmethodswouldbehighlyrecommendable.ModernTGAanalyzersnotonlyreducehumanerrorsthroughautomizationbut,thankstoflexibleuseofcarriergasandtemperatures,providemanifoldpossibilitiestocharacterizeSiCandrelatedproducts.Author:Dr.AndreKlostermeierProductManagerELTRAGmbHPhone:+49(0)2104/2333-300E-Mail:a.klostermeier@eltra.comLiterature[1]RmpChemieLexikon,10thedition(2002)[2]ENISO21068(2008),Parts1,2,3[詳細(xì)]
-
2018-08-16 10:00
產(chǎn)品樣冊
-
Silicon carbide ( SiC nano particles)粒度分析報告
- Silicon carbide ( SiC nano particles)粒度分析報告[詳細(xì)]
-
2024-09-28 00:01
實驗操作
-
Porous silicon composite material
- Porous silicon composite material[詳細(xì)]
-
2015-09-28 00:00
標(biāo)準(zhǔn)
-
Porous silicon composite material
- Porous silicon composite material[詳細(xì)]
-
2024-09-28 09:31
產(chǎn)品樣冊
-
Combustion Module-CRDS for 13C analysis
- Combustion Module-CRDS for 13C analysis[詳細(xì)]
-
2024-09-15 08:06
期刊論文
-
Effective Quality Control of Steel and Iron Products with Combustion Analysis
- Effective Quality Control of Steel and Iron Products with Combustion Analysis[詳細(xì)]
-
2015-06-24 00:00
專利
-
SID4 Element
- SID4 Element[詳細(xì)]
-
2023-02-16 14:34
應(yīng)用文章
-
The reversible wettability of Ti containing amorphou
- The reversible wettability of Ti containing amorphou[詳細(xì)]
-
2006-01-13 00:00
操作手冊
-
Quality Control of Coal with Elemental Analyzers
- Quality Control of Coal with Elemental Analyzers[詳細(xì)]
-
2015-06-24 00:00
標(biāo)準(zhǔn)
-
LactoScope FTIR Dairy Analyzers Brochure
- LactoScope FTIR Dairy Analyzers Brochure[詳細(xì)]
-
2024-09-14 05:25
應(yīng)用文章
-
Simultaneous Impedance measurements on each element
- Simultaneous Impedance measurements on each element[詳細(xì)]
-
2008-10-30 00:00
選購指南
-
Q-POD Element 終端精制器
- Q-POD Element 終端精制器[詳細(xì)]
-
2024-09-20 00:04
安裝說明
-
Surface energy of metal containing amorphous carbon
- Surface energy of metal containing amorphous carbon[詳細(xì)]
-
2024-09-28 21:36
產(chǎn)品樣冊
-
A&D MS-70/MX-50/MF-50 Moisture Analyzers Brochure
- A&D MS-70/MX-50/MF-50 Moisture Analyzers Brochure[詳細(xì)]
-
2016-05-23 00:00
應(yīng)用文章
-
Dilatometer--Thermomechanical analysis
- Dilatometer--Thermomechanical analysis[詳細(xì)]
-
2012-06-01 00:00
操作手冊
-
Analysis of Glycerine
- Analysis of Glycerine[詳細(xì)]
-
2024-09-29 19:18
其它
-
Q-POD Element終端精制器產(chǎn)品樣冊
- Q-POD Element終端精制器產(chǎn)品樣冊[詳細(xì)]
-
2016-10-19 17:47
操作手冊
-
Oxidation Profile Analysis
- Oxidation Profile Analysis[詳細(xì)]
-
2004-02-19 00:00
實驗操作
-
Food Analysis by 300-MS
- Food Analysis by 300-MS[詳細(xì)]
-
2010-08-11 00:00
選購指南
Copyright 2004-2026 yiqi.com All Rights Reserved , 未經(jīng)書面授權(quán) , 頁面內(nèi)容不得以任何形式進(jìn)行復(fù)制
參與評論
登錄后參與評論